Search results for " Crystalline"
showing 10 items of 152 documents
Isomerisation of Liquid-Crystalline Tristriazolotriazines
2017
Star-shaped discotic liquid crystals with columnar superstructures constitute a highly interesting class of organic materials. Phenyl-substituted tris[1,2,4]triazolo-[1,3,5]triazine, prepared by a Huisgen reaction of phenyltetrazole and cyanuric chloride, represents an excellent core for discotic liquid crystals (DLCs). The thermal stability is not perfect, at temperatures above the clearing point, a successive threefold isomerization leads to a highly planar, C
Non-essential role for cilia in coordinating precise alignment of lens fibres
2016
The primary cilium, a microtubule-based organelle found in most cells, is a centre for mechano-sensing fluid movement and cellular signalling, notably through the Hedgehog pathway. We recently found that each lens fibre cell has an apically situated primary cilium that is polarised to the side of the cell facing the anterior pole of the lens. The direction of polarity is similar in neighbouring cells so that in the global view, lens fibres exhibit planar cell polarity (PCP) along the equatorial-anterior polar axis. Ciliogenesis has been associated with the establishment of PCP, although the exact relationship between PCP and the role of cilia is still controversial. To test the hypothesis t…
Objective Assessment of Nuclear and Cortical Cataracts through Scheimpflug Images: Agreement with the LOCS III Scale.
2016
Purpose To assess nuclear and cortical opacities through the objective analysis of Scheimpflug images, and to check the correlation with the Lens Opacity Classification System III (LOCS III). Methods Nuclear and cortical opacities were graded according to the LOCS III rules after pupil dilation. The maximum and average pixel intensity values along an elliptical mask within the lens nucleus were taken to analyse nuclear cataracts. A new metric based on the percentage of opaque pixels within a region of interest was used to analyse cortical cataracts. The percentage of opaque pixels was also calculated for half, third and quarter areas from the region of interest’s periphery. Results The maxi…
Cohen Syndrome-Associated Cataract Is Explained by VPS13B Functions in Lens Homeostasis and Is Modified by Additional Genetic Factors
2020
International audience; Purpose: Cohen syndrome (CS) is a rare genetic disorder caused by variants of the VPS13B gene. CS patients are affected with a severe form of retinal dystrophy, and in several cases cataracts also develop. The purpose of this study was to investigate the mechanisms and risk factors for cataract in CS, as well as to report on cataract surgeries in CS patients.Methods: To understand how VPS13B is associated with visual impairments in CS, we generated the Vps13b∆Ex3/∆Ex3 mouse model. Mice from 1 to 3 months of age were followed by ophthalmoscopy and slit-lamp examinations. Phenotypes were investigated by histology, immunohistochemistry, and western blot. Literature anal…
Influences of Ortho‐Fluoroazobenzenes on Liquid Crystalline Phase Stability and 2D (Planar) Actuation Properties of Liquid Crystalline Elastomers
2019
1985
Etude de polyesters avec du triphenylene ou du benzene comme cœur du discogene et des espaces flexibles alkylene
Preoperative simulation of postoperative iris-fixated phakic intraocular lens position and simulation of aging using high-resolution Scheimpflug imag…
2006
To increase postoperative safety after implantation of iris-fixated phakic intraocular lenses (pIOLs), optimal preoperative evaluation and patient selection is mandatory. We present a new software tool in a high-resolution Scheimpflug imaging device that precisely simulates the postoperative position of an iris-fixated pIOL and also simulates the effect of aging on the pIOL's position.
A simple description of age-related changes in crystalline lens thickness.
2010
Purpose An increase in lens thickness is often described as a linear function of age. However, contradictory opinions exist about whether the lens thickness continues to increase after 50 years of age. Differences in slope exist between this increase in younger and older people, but these findings are inconsistent with the linear behavior of an increase in the lens thickness throughout life. We investigated among different functions, including slope variation, which would be the best to show the relation between lens thickness and age. An available model portraying lens growth could be advantageous in many practical applications. The possibility of differences between sexes in lens thicknes…
Spectral Transmission of the Human Crystalline Lens in Adult and Elderly Persons: Color and Total Transmission of Visible Light
2012
Purpose To experimentally measure the spectral transmission of human crystalline lenses belonging to adult and elderly persons, and to determine the color and total transmission of visible light of such crystalline lenses. Methods The spectral transmission curve of 32 human crystalline lenses was measured using a PerkinElmer 800UV/VIS spectrometer. Total transmission of visible light and the chromatic coordinates of these crystalline lenses were determined from these curves for solar illumination. Results The crystalline lens that filters UV and its transmission in the visible spectrum decreases with age; such a decrease is greater for short wavelengths. The total transmission of visible li…
Repeatability assessment of biometric measurements with different refractive states and age using a swept-source biometer
2018
Background We aim to assess if refractive error or age may influence the repeatability of measurements using a swept-source biometer. Methods A total of 61 subjects were evaluated with IOLMaster 700 acquiring measurements of axial length (AL), central corneal thickness (CCT), white-to-white distance (WTW), anterior aqueous depth (AQD), lens thickness (LT), and keratometry (K) readings. Repeatability was evaluated classifying the sample according to the refractive state and age by the calculation of the within-subject standard deviation (Sw), coefficient of repeatability, and intraclass correlation coefficient. Results Very similar Sw was acquired among groups for AL, CCT, and WTW. Differenc…